MRI Non-Magnetic Pneumatic Transport Ventilator
MRI Non-Magnetic Pneumatic Transport Ventilator is a small, lightweight transport ventilator designed for use on patients from pediatric to adult in size.
This ventilator has simple -to-use controls for volume-targeted or pressure-limited ventilation. With a built-in high output demand flow CPAP system, critical care ventilation needs are optimized for spontaneous and mandatory breaths. Operating without the need of electrical power, the ventilator can care for the most difficult patients wherever they may be located.
Use this ventilator as your key to an all hazards approach to mechanical ventilatory support. Be prepared for any emergency or loss of electrical power.
Use this ventilator in your ambulance, on your aircraft, within MRI or wherever you need mechanical ventilation.
Benefits
All pneumatic operation, no batteries or external power needed to provide ventilation
Switch from noninvasive face mask ventilation to invasive ventilation seamlessly and without interruption
Low spontaneous work of breathing compared to other transport ventilators
Built-in CPAP / PEEP system with automatic sensitivity for changing patient needs means no need for external CPAP valves
Mandatory and spontaneous breaths at 100% or use 65% oxygen to prolong your oxygen tanks
MRI compatible with remote alarm capability so you can meet patient needs in your special procedure areas
Integrated all-pneumatic alarm system keeps you alerted to patient circuit disconnects and a low gas supply
Designed for ventilating patients in pre-hospital and hospital areas
Disaster Preparation
Air / Ground Ambulance
Emergency Department
In-Hospital Transports
Intensive Care Unit
Post-Anesthesia Recovery Rooms
MRI and other Radiology Suites
Military Field Hospital and Evacuation
Recommended VE-5001 & VE-5002(Remote Alarm with Cable) for use with this product
Description:
Pneumatically operated
Intended for use on pediatric/adult patients, 23 kg and above
Demand flow system for spontaneous breathing up to 140 L/min
Pressures displayed on manometer
Modes of Operation: IMV, CPAP
Mandatory breath flow rate is fixed at 36 L/min
Visual and audible patient disconnect alarm system with remote output for use in areas where the patient cannot be directly monitored (MRI)
MRI compatible: up to 3.0 T static field strength, 6.9 G/cm spatial field gradient, 300 V RF power, shielded
Weight: 6.6 pounds (3.0 kg)
Dimensions: 5"H x 10"W x 7"D (13 x 25 x 18 cm)
Input gas requirement: 55 psi + 15 psi (3.8 bar + 1 bar)
Meets International Standards for transport Ventilators: ~ ASTM: Ventilators Intended for Use in Critical Care (F 1100-90) ~ ISO: Lung Ventilators for medical use, Part 3 (10651-3)
Control Settings:
Visual and Audible Alarms:
All pneumatic alarm system (no batteries) that is always on
Patient circuit disconnection
Low oxygen inlet pressure (below 30 psi)
Automatic reset
1 minute silence / reset button
Remote alarm output