MRIequip.com | MRI Safety

Safety is our Business

Our dedication to safety begins at 7:00 a.m. every day of the work week - it is our livelihood. All products in our warehouse are checked on entry and then re-checked on exit. Products drop shipped from our manufacturers directly to your door are brought in randomly and re-tested for safety verification. We continually work with all manufacturers to ensure safety and proper designation.
 
For more information on the ASTM Standard visit http://www.astm.org and search for F2503-05.
 
For more helpful information pertaining to MR Safety, you can visit www.MRI-Planning.com
www.MRISafety.com
 
The highly anticipated Standard Practice for Marking Medical Devices for Safety in the Magnetic Resonance Environment by American Society for Testing and Materials (ASTM) has arrived.
 
As recommended by ASTM Intl.; The intent of this practice is to provide needed information about the safety of items in and near MR scanners using a compact and easily recognized set of symbols and terms. The terms MR safe and MR compatible as first defined in 1997 in the FDA draft guidance document, "A Primer on Medical Device Interactions with Magnetic Resonance Imaging Systems, have been used to describe the safety of devices in and near MR systems. However, there has been a great deal of confusion surrounding this terminology. An incorrect assumption is often made. Users often incorrectly assume that items labeled MR safe or MR compatible are safe or compatible for any MR environment. MR environments vary in terms of magnetic field strength and RF conditions. This new system eliminates much of that confusion.

MR Safe - an item that poses no known hazards in all MR environments.


MR Conditional - an item that has been demonstrated to pose no known hazards in a specified MR environment with specified conditions of use. Field conditions that define the specified MR environment include field strength, spatial gradient, dB/dt (time rate of change of the magnetic field), radio frequency (RF) fields, and specific absorption rate (SAR.) Additional conditions, including specific configurations of the item, may be required.

MR Unsafe - an item that is known to pose hazards in all MR environments.


CE Certification - these products comply with the essential requirements of the relevant European health, safety and environmental protection legislation.


Product NOT marked with a designation has been tested under the past methods and is currently being re-evaluated under the new ASTM Standards. Products will be updated continually.

About Us

Products Determined to be MR Conditional at 7-T or Less.

Now, at your fingertips, is a diverse line of Non-Ferrous and Stainless Steel products for your MRI environment that are MR Conditional at 7-T or less. These items tested represent many of the important patient support products that are commonly used in clinical MRI environments.

Stainless Steel Products Determined to be MR Conditional at 7-T or Less

Non-Ferromagnetic Products Determined to be MR Conditional at 7-T or Less